12v battery,12V 24ah solar battery

12v battery,12V 24ah solar battery
Product Detailed
12v battery,12V 24ah solar battery 1.Free maintenance 2.Excellent cycle and float life 3.CE/ISO9001/MSDS 4.Use of safety

12v battery,12V 24ah solar battery

Detail Specifications of solar battery 12v 24ah :* Model: NP24-12 12V lead acid battery* Nominal Voltage: 12V lead acid battery* Rated Capacity: 24Ah(10Hr)* Dimension: 166(L)*125(W)*175(H)mm* Approx Weight: 7.7KG/pcs 12V lead acid battery* Packing Detail: 2pcs/CTN 12V lead acid battery* Loading Quantities: 20'FT=1125PCS Main Features of 12V 24ah battery   :

1. Excellent safety performance: No electrolyte leakage, battery swelling and cracking under normal use. 2. Good discharging performance: With smooth discharging voltage and mild discharging platform.

3. Good shock-proof performance: The fully charged and completely fixed battery, with 4mm amplitude and 16.7Hz frequency do have a normal open circuit voltage without leakage, batteries swelling or cracking problem after one-hour vibration. 4. Good impact-proof performance: The fully charged battery is proved to maintian normal open circuit voltage and be without leakage or batteries swelling or cracking after droping three times from 20cm height naturally to a 1 cm-thick hardwood board. 5. Good resistance to overdischarge: In temperature of 25 degrees Celsius, the fully charged battery discharges with fixed resistance which is equivalent to the one required by 1 CA discharge of the battery for three weeks, and it can restore capacity over 75%. 6. Good resistance to overcharge: The fully charged battery is proved to maintian normal open circuit voltage and be without leakage or batteries swelling or cracking in temperature of 25 degrees Celsius after chargeing at 0.1 CA for 48 hours, and the capacity maintian over 95%. 7. Good resistance to high current: The fully charged battery is proved to be without conductive part melted or any appearance deformation after discharging at 2 CA for 5 minutes or 10 CA for 5 seconds. Application Alarm system Emergency lighting system Electronic instrument Telecommunication system Solar energy generating system Wind energy generating system UPS and computer standby power supply Fire-fighting equipment standby power supply 

 Applications of 12V 24ah  battery   : 1.Telephone switchboards, electric equipments, medical equipments, medical instruments and meters2.Computers and uninterrupted power source (UPS)

3.Power transmission and transformer station, switch control and accident lighting

4.Fire fighting, safety device and alarm monitoring5.Aviation, spaceflight and power storage6.Automatic office system7.Radio communication system8.Emergency lighting and car and ship starting system9.Portable electric appliances and mining system10. Solar energy systems  Cautions Installation Notice (1) Lay the battery with up-down direction instead of put it inverted in any case (2) Abnormal vibration or shock is not allowed. (3) Do insulate when installation. (4) Make the batteries ventilated and gapped. (5) Do not mixed up different brand and manufacturing date batteries. (6) Separate the batteries from organic solvent. Application Notice 1, Ensure the application conditions to be in compliance with manufacturer's specification requirement. 2, Charge battery to full at the first using or after long term storage. 3, Since installed in UPS, the battery life cycle will be seriously affected if the operating frequency is high. 4, Inspect lead-acid battery regularly. 5, Do replace a new battery if the ABS container is deformed or leaking. 6, Fire risk exists if the wires do not joint tightly at terminal. 7, Discharge once every three months is recommendable under no power-off condition. If charging voltage and discharging characteristic is abnormal, pls replace the battery soon. 8, Replace the battery if capacity less than 50% of rated capacity. Specifications of 12V 24ah  battery :  
Nominal Voltage12V
Rated capacity(20 hour rate) 24AH
DimensionsLength   166±1mm(6.54 inches)
Width   125±1mm(4.92inches)
Height   175±1mm(6.89inches)
Total Height   175±1mm(6.89 inches)
Weight Approx   7.7kg
 
Capacity 25°C    10 hour rate(2.21A, 10.50V)    24.00AH
    5 hour rate(4.08A, 10.50V)    20.40AH
    1 hour rate(14.40A, 9.60V)    14.40AH
Internal ResistanceFull charged Battery at 25 °C (77°F)    12mΩ
Capacity affected by temperature (20 hour rate)40°C(104°F)102%
25°C(77°F)100%
0°C(32°F)85%
-15°C(5°F)65%
Self-Discharge at 25°C(77°F)Capacity after 3 month storage91%
Capacity after 6 month storage82%
Capacity after 12 month storage64%
Charge (constant voltage)Cycle

Initial Charging Currentless than 7.20A

Voltage14.40-15.00 V

FloatVoltage 13.50-13.80V
Terminal  T32
    